Ambient conditions

Dew point and spread table

The dew point is the temperature at which moisture condenses. The values below use the Magnus formula (a = 17.625, b = 243.04), the same calculation the CoatSpec tool runs on your inputs.

Common field practice, reflected in many specifications, is to require the surface temperature to be at least 3 degrees Celsius (5 degrees Fahrenheit) above the dew point during application and initial cure, with relative humidity at or below 85 percent. Your project specification governs - some coatings carry different limits.

Dew point in °C by air temperature and relative humidity (Magnus formula). Surface must typically stay 3 °C above these values.
Air (°C)30% RH40% RH50% RH60% RH70% RH80% RH90% RH
0-15.5-12-9.2-6.8-4.8-3-1.4
5-11.2-7.5-4.6-2.101.83.5
10-6.8-302.64.86.78.4
15-2.41.54.77.39.611.613.4
201.969.31214.416.418.3
256.210.513.916.719.121.323.2
3010.514.918.421.423.926.228.2
3514.819.42326.128.73133.1
4019.123.827.630.833.535.938

Frequently asked questions

Why must the surface be 3 degrees Celsius above the dew point?

As the surface approaches the dew point, a molecular film of moisture can form even before visible condensation, risking flash rusting on steel and adhesion loss for most coatings. The 3 C / 5 F spread is a widely used safety margin - verify what your specification requires, since some products have their own limits.

When during the shift should conditions be measured?

As commonly applied, at least before start-up and every four hours thereafter, and more often when conditions are changing - rising humidity, falling temperature, or work moving between sun and shade. Log every set of readings with the instrument used.

Does the table replace a dew point meter?

No. It shows the arithmetic relationship so you can sanity-check readings. Field acceptance should rest on calibrated instruments measured at the work location.